SL. MWID Description Last Log
1 856 DTW-206 PIT isn't working. Need to check. 01st June 2024 01:30:02 PM
2 857 1 Nos bullet camera isolation from IRP-2 Sub-Station room due to installation of Air Conditioner. 01st June 2024 01:33:15 PM
3 858 IRP-1 SFB all ultrasonic level sensor clean. 01st June 2024 04:56:49 PM
4 859 IRP-2 SFB all ultrasonic level sensor clean. 01st June 2024 04:57:30 PM
5 862 Dtw 115 VFD fault needs to be checked. 04th June 2024 04:33:26 AM
6 863 DTW-110, LIT, PIT, FIT re-installation after regeneration. 04th June 2024 02:42:44 PM
7 864 DTW-212 ACB Tripped problem. Need to check ICE team. 05th June 2024 05:24:40 PM
8 865 FIT LAYOUT need to be checked. FIT- 3001 and FIT 3004. Wrong value is showing. 06th June 2024 09:57:49 AM
9 866 DTW-221 VFD Problem. Need to check ice team. 06th June 2024 09:39:39 PM
10 867 Dtw-207 SCADA Pack Programming & Installation. 07th June 2024 09:32:54 PM
11 869 Dtw 221 cc camera view is not showing. Need to be check. 09th June 2024 10:17:43 AM
12 868 SCADA Operation pc-01 memory low showing. Need to check. 09th June 2024 04:08:03 PM
13 871 DTW-117 Command not accept from SCADA. Need to check. 09th June 2024 04:16:56 PM
14 873 DTW-113 Suddenly VFD fault is showing. Need to check ice team. 11th June 2024 05:41:05 AM
15 872 Dtw 104 CCTV footage not showing 11th June 2024 09:39:56 AM
16 874 Dtw 109 CCTV footage not showing 11th June 2024 09:40:51 AM
17 870 Dtw 121 CCTV camera catching/cover need to adjust on the pol 11th June 2024 09:46:39 AM
18 875 Dtw 119 CCTV footage not showing 11th June 2024 10:30:36 AM
19 876 Dtw 104 communication error.now it's locally running.need to check 11th June 2024 01:19:14 PM
20 877 Dtw 115 communication error.now it's locally running 11th June 2024 01:20:07 PM
21 878 DTW-207 Inverter (VFD) fault problem. Need to check by ICE team. 12th June 2024 09:25:28 AM
22 879 Irp-1 to irp-2 fibre optic communication error.need to check urgently 12th June 2024 11:58:46 AM
23 880 Dtw 114 Suddenly VFD fault. Field check, problem not solved. Need to check. Vfd fault that is why the local water supply can't operate 15th June 2024 01:28:51 PM
24 881 Suddenly IRP-01 to IRP-02 Optical (FO) Communication error. Need to check ice team. 17th June 2024 02:39:44 AM
25 882 Dtw 122 MC Problem. Need to change. Now the pump stops. 18th June 2024 05:08:06 PM
26 883 Dtw 103 Radio communication Error. Need to check. We can't operate the Local water supply from the SCADA System. 19th June 2024 01:02:12 PM
27 884 Dtw 113-123 CCTV footage not showing 21st June 2024 08:11:33 AM
28 885 Dtw 114 inverter fault showing 22nd June 2024 10:23:08 AM
29 886 Dtw 103 radio communication problem .now it's locally running 26th June 2024 08:50:20 AM
30 887 Dtw 104 Suddenly stop. Start stop problem. Need to check. 27th June 2024 04:14:06 AM
31 888 Irp-2 inside 2 no's CCTV (PTZ) not showing 29th June 2024 12:32:22 PM
32 889 Irp1 Sand filter bed area one drone camera view automatically rotates. Need to check 30th June 2024 10:54:36 AM
33 890 Dtw 114 Local Water Supply MOV -01 MOV not fully closed. Need to check 30th June 2024 01:13:37 PM